<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Stadium Power &#187; Fire and Security</title>
	<atom:link href="http://www.stadiumpower.co.uk/category/fire-and-security/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.stadiumpower.co.uk</link>
	<description>Custom and standard power supplies from Stadium Power</description>
	<lastBuildDate>Mon, 06 Sep 2010 13:27:10 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>SBC-EN54-27V6-5A0</title>
		<link>http://www.stadiumpower.co.uk/battery-chargers/battery-chargers-battery-chargers/27v6-27v-5a-battery-charger-en54/</link>
		<comments>http://www.stadiumpower.co.uk/battery-chargers/battery-chargers-battery-chargers/27v6-27v-5a-battery-charger-en54/#comments</comments>
		<pubDate>Thu, 12 Aug 2010 16:10:00 +0000</pubDate>
		<dc:creator>marc1</dc:creator>
				<category><![CDATA[Battery Chargers]]></category>
		<category><![CDATA[Fire and Security]]></category>

		<guid isPermaLink="false">http://www.stadiumpower.co.uk/?p=2941</guid>
		<description><![CDATA[<p>138W with battery backup facility<br />
27.6Vdc output.<br />
4A load current / 1A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 149Lmm x 122Wmm  x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
200-230Vac input +/-10%</p>
]]></description>
			<content:encoded><![CDATA[<p>138W with battery backup facility<br />
27.6Vdc output.<br />
4A load current / 1A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 149Lmm x 122Wmm  x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
200-230Vac input +/-10%</p>
]]></content:encoded>
			<wfw:commentRss>http://www.stadiumpower.co.uk/battery-chargers/battery-chargers-battery-chargers/27v6-27v-5a-battery-charger-en54/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SBC-EN54-27V6-2A0</title>
		<link>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-2a-battery-charger-en54/</link>
		<comments>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-2a-battery-charger-en54/#comments</comments>
		<pubDate>Wed, 25 Nov 2009 15:59:43 +0000</pubDate>
		<dc:creator>marc1</dc:creator>
				<category><![CDATA[Battery Chargers]]></category>
		<category><![CDATA[Fire and Security]]></category>

		<guid isPermaLink="false">http://www.stadiumpower.co.uk/?p=2592</guid>
		<description><![CDATA[<p>55W with battery backup facility<br />
27.6Vdc output<br />
1.8A load current / 0.35A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
Universal AC Input</p>
]]></description>
			<content:encoded><![CDATA[<p>55W with battery backup facility<br />
27.6Vdc output<br />
1.8A load current / 0.35A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
Universal AC Input</p>
]]></content:encoded>
			<wfw:commentRss>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-2a-battery-charger-en54/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SBC-EN54-27V6-3A0</title>
		<link>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-3a-battery-charger-en54/</link>
		<comments>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-3a-battery-charger-en54/#comments</comments>
		<pubDate>Thu, 30 Jul 2009 08:24:33 +0000</pubDate>
		<dc:creator>staceyscullion</dc:creator>
				<category><![CDATA[Battery Chargers]]></category>
		<category><![CDATA[Fire and Security]]></category>

		<guid isPermaLink="false">http://www.stadiumpower.co.uk/?p=2359</guid>
		<description><![CDATA[<p>80W with battery backup facility<br />
27.6Vdc output.<br />
2.4A load current / 0.6A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
200-230Vac input +/-10% </p>
]]></description>
			<content:encoded><![CDATA[<p>80W with battery backup facility<br />
27.6Vdc output.<br />
2.4A load current / 0.6A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
200-230Vac input +/-10% </p>
]]></content:encoded>
			<wfw:commentRss>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-3a-battery-charger-en54/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SBC-EN54-13V8-5A0</title>
		<link>http://www.stadiumpower.co.uk/battery-chargers/13v8-5a-battery-charger-en54/</link>
		<comments>http://www.stadiumpower.co.uk/battery-chargers/13v8-5a-battery-charger-en54/#comments</comments>
		<pubDate>Thu, 30 Jul 2009 08:23:21 +0000</pubDate>
		<dc:creator>staceyscullion</dc:creator>
				<category><![CDATA[Battery Chargers]]></category>
		<category><![CDATA[Fire and Security]]></category>

		<guid isPermaLink="false">http://www.stadiumpower.co.uk/?p=2355</guid>
		<description><![CDATA[<p>80W with battery backup facility<br />
13.8Vdc output.<br />
4A load current / 1A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
200-230Vac input +/-10%</p>
]]></description>
			<content:encoded><![CDATA[<p>80W with battery backup facility<br />
13.8Vdc output.<br />
4A load current / 1A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 49.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
200-230Vac input +/-10%</p>
]]></content:encoded>
			<wfw:commentRss>http://www.stadiumpower.co.uk/battery-chargers/13v8-5a-battery-charger-en54/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SBC-EN54-27V6-1A5</title>
		<link>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-1a-battery-charger-en54/</link>
		<comments>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-1a-battery-charger-en54/#comments</comments>
		<pubDate>Thu, 30 Jul 2009 08:22:06 +0000</pubDate>
		<dc:creator>staceyscullion</dc:creator>
				<category><![CDATA[Battery Chargers]]></category>
		<category><![CDATA[Fire and Security]]></category>

		<guid isPermaLink="false">http://www.stadiumpower.co.uk/?p=2352</guid>
		<description><![CDATA[<p>48W with battery backup facility<br />
27.6Vdc output.<br />
1.2A load current / 0.35A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 39.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
Universal AC Input </p>
]]></description>
			<content:encoded><![CDATA[<p>48W with battery backup facility<br />
27.6Vdc output.<br />
1.2A load current / 0.35A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 39.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
Universal AC Input </p>
]]></content:encoded>
			<wfw:commentRss>http://www.stadiumpower.co.uk/battery-chargers/27v6-27v-1a-battery-charger-en54/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SBC-EN54-13V8-3A0</title>
		<link>http://www.stadiumpower.co.uk/battery-chargers/13v8-13v-3a-battery-charger-en54/</link>
		<comments>http://www.stadiumpower.co.uk/battery-chargers/13v8-13v-3a-battery-charger-en54/#comments</comments>
		<pubDate>Thu, 30 Jul 2009 08:19:44 +0000</pubDate>
		<dc:creator>staceyscullion</dc:creator>
				<category><![CDATA[Battery Chargers]]></category>
		<category><![CDATA[Fire and Security]]></category>

		<guid isPermaLink="false">http://www.stadiumpower.co.uk/?p=2346</guid>
		<description><![CDATA[<p>48W with battery backup facility<br />
13.8Vdc output<br />
2.4A load current / 0.6A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 39.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
Universal AC Input </p>
]]></description>
			<content:encoded><![CDATA[<p>48W with battery backup facility<br />
13.8Vdc output<br />
2.4A load current / 0.6A current limited battery charge<br />
Incorporates latest battery impedance test<br />
0-50 DegC operating range<br />
Advanced monitoring circuitry and alarms signals<br />
Enclosed format with dimensions 124Lmm x 122Wmm  x 39.5Hmm<br />
Applications: fire alarm panels, access control, CCTV, security lighting<br />
High performance<br />
Universal AC Input </p>
]]></content:encoded>
			<wfw:commentRss>http://www.stadiumpower.co.uk/battery-chargers/13v8-13v-3a-battery-charger-en54/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>